Partition Coefficient (K)
Definition
Here defined as equilibrium liquid concentration divided by gas concentration. It depends on analyte, matrix and conditions; state the convention before interpretation.
- Definition
- Liquid-phase to gas-phase ratio at equilibrium
- Ethanol in blood at 60C
- Approximately 1,200 to 1,400
- Lower K effect
- Favours headspace concentration
- Method
- GC-headspace
Common questions
Why does a lower partition coefficient favour headspace analysis?+
A lower K means proportionally more analyte moves into the gas phase at equilibrium, giving a stronger headspace signal that is easier to detect and quantify by gas chromatography.
What affects the partition coefficient of ethanol in blood?+
Temperature is the main factor. Raising the equilibration temperature increases the proportion of ethanol in the headspace, which is why headspace methods use tightly controlled heating.
Related terms
- 2100:1 Partition Ratio
- A conventional blood-to-breath concentration ratio, not a universal physiological constant. At this ratio, 2100 volumes of breath contain the same ethanol mass...
- Beta Elimination Rate (Beta)
- The rate at which BAC falls during the post-absorptive phase of alcohol metabolism, expressed as mg/100 mL/hour. Population mean approximately 15 mg/100...
- Blood Alcohol Concentration (BAC)
- Mass of ethanol per unit volume of whole blood, expressed as mg per 100 mL (equivalent to mg/dL or mg%), or as...
- DB-ALC1 / DB-ALC2
- Examples of manufacturer-specific blood-alcohol chromatography columns. Different stationary-phase selectivities can help reveal interference. Verify proprietary chemistry and method suitability from current documentation.
- Internal Standard (IS)
- A compound chemically near-identical to the analyte, often a deuterated isotopologue (d3-morphine, d5-EDDP, d5-alprazolam, pyrene-d10), spiked into every sample at a known...
- NIST SRM 1828
- A series of NIST-certified reference material aqueous ethanol standards (0.02 to 0.40 per cent w/v) used to calibrate forensic blood ethanol analytical...
- Sodium Fluoride / Potassium Oxalate (Grey-Top Tube)
- The standard blood collection tube for forensic ethanol analysis. Sodium fluoride inhibits microbial fermentation (which would produce artefactual ethanol post-collection); potassium oxalate...
- Static Headspace
- A sample preparation technique in which a sealed vial is heated until volatile analytes reach thermodynamic equilibrium between the liquid matrix and...
- Widmark Factor (Rho / R)
- A dimensionless pharmacokinetic constant that represents the distribution of ethanol across body water. Averages approximately 0.68 for adult males and 0.55 for...