When two tools disagree about a mobile artifact, compare their inputs, settings and output categories. Then trace the disagreement to the underlying records and test the field interpretation against independent evidence. A polished report or a majority vote cannot substitute for knowing what the tool interpreted.

Start with the discrepancy that matters to the case. One tool may show an outbound item while another leaves direction unknown. Before choosing an interpretation, verify that both refer to the same record and data state. Document what the independent check resolves and what remains open.

Key terms

Parser
Software that reads a source format and produces structured values or labels.
Source state
The files, versions and related records interpreted at the time of examination.
Field mapping
The rule used to translate a raw value into a displayed meaning.
Known test data
Controlled examples whose relevant inputs and expected outcomes are documented.
Independent verification
Checking a result using evidence or a method that does not rely on the same unsupported assumption or transformation.
Input state
The files, companion material and versions actually supplied to a tool. Compare input states before interpreting a difference as a decoder defect.
More key terms (2)
Presentation filter
An option that changes which decoded records are displayed or exported. Distinguish a hidden row from a missing acquisition result.
Independent check
A verification against the underlying source, a documented rule or a known test input. A second viewer that uses the same parser may reproduce the same interpretation.

By the end of this topic, you will be able to do the following.

  • Define a disagreement at the level of a record and field.
  • Distinguish differences in source coverage, parsing and display.
  • Compare the underlying data with app documentation and known examples.
  • Document a resolved or unresolved discrepancy for another examiner.

Identify Where the Results Diverge

A difference in totals can come from separate filters, categories or duplicated representations. A label difference can result from one parser applying a default while another leaves a field blank. A time difference can come from display settings or from interpreting two different timestamps. Identify the source record and disputed claim first. The case might turn on one direction label while other differences have little effect on the answer.

Work back to the source record. Compare filters for different counts, field interpretation for different labels and time bases for different timestamps.

Scroll horizontally if needed to see the full table.

DisagreementFirst comparisonUseful evidence to retain
One output lacks a rowInput completeness, source state, inclusion filters and warningsFile inventory, acquisition reference and tool settings
Direction differsUnderlying field, app schema version and mappingRaw value, table and row reference
Times disagreeTimestamp field, raw value, precision and display zoneOriginal format, tool settings and documented event meaning
Counts differCategory membership, duplicates and summary rulesRow references and counting method
Same result appears twiceShared parser, library or exported intermediate tableTransformation history and separate verification where available

When the source is SQLite in write-ahead logging (WAL) mode, the associated WAL file can be part of the database’s persistent state. Comparing the main database file alone with a documented assembled source can yield different rows for reasons unrelated to a parser’s mapping. Verify which components were supplied and which the tools used. Preserve originals and follow the lab’s procedure for using working copies. SQLite documentation on write-ahead logging

The Scientific Working Group on Digital Evidence (SWGDE) discusses verifying mobile artifacts from the underlying data and using corroboration where available. For either Android or iOS, review the disputed field against the app version and workflow at issue. A tool that works on another version or device class may still mislabel a field in the one being examined. SWGDE mobile analysis guidance, version 1.0

Record the Verification Method Before Re-running the Tools

Save the versions, inputs, settings, quoted result and working-copy reference from each run. A later export or updated parser could change a result before a reviewer can reconstruct the first comparison. Keep any new run as a separately identified result. If the tool does not expose its assumptions, write down what was observed and which parts of the transformation remain undocumented.

Plan the independent check around a known positive and a known comparison case. For an event code that might distinguish imports from transmissions, an accurate result on an import sample proves little if the tool labels every record import. A separate known transmission tests whether the approach distinguishes the two outcomes. Where the decision depends on an app version or record subtype, choose examples that cover that exact context. If the supplied evidence leaves the version uncertain, resolve that source question before borrowing a mapping.

A meaningful validation uses both a known positive and a different event under the relevant app version. Testing an import alone leaves an always-import mapping undetected.

Compare the Input, Decoded Record and Report Separately

Two tools can disagree at three points. They may receive different versions of the evidence, decode the same field differently, or display different subsets of the records they decoded. Start with the file inventory and the tool’s input log. Then compare the decoded record, using the source’s own record identifier where it is available. Finally compare the report settings, including filters, grouping and time-zone conversion.

Scroll horizontally if needed to see the full table.

Where the results divergeWhat to checkWhat you can establish
InputSource references, file inventory and relevant companion filesWhether both tools examined a comparable dataset
DecodingRaw field, app or schema version and result from an app-specific checkWhether the reported label follows from the field
PresentationReport filters, grouped rows, selected categories and display time basisWhether the report omits, combines or reformats a decoded result

These checks can expose more than one difference. For example, a single row could be absent from one tool’s input and mislabelled by the other. Keep separate notes for the missing row and the misleading label. An explanation for one output does not account for the other. SWGDE best practices for mobile device forensic analysis

The same case can have an input gap in one tool and a label difference in another. Keep the run references separate so each discrepancy has its own evidence.

Decide Whether a Second Result Can Confirm the First

A second report can repeat the first tool’s interpretation. If the two viewers use the same parser or both start from the same processed export, agreement may show that the downstream views are consistent. To test what the source field means, use the underlying value, a documented version-specific definition, or test records with independently observed events.

In a practice exercise, two viewers classify a dispatch event as confirmed. Both read the same intermediate export. An authorized test dataset from the same app build includes a confirmation request and a separately observed confirmation. The shared parser gives both test records the same label. A useful review note records the two inputs, the expected distinction and the labels observed. This identifies the scope of the problem and tells the reviewer which other findings depend on the same interpretation.

Agreement between viewers that share a processed export can reflect the same parser decision. In this practice test, independent observations show that the parser collapses two different events into one label.

If you cannot establish the meaning of the disputed field, retain the source value and record the disagreement. A report could establish that a record was present and that neither interpretation could be verified from the available sources. Give the reader the app version and record reference so a later reviewer can pick up the unresolved question.

Test a Parser Disagreement Against the Original Record

A fictional iPhone examination compares two tool reports for an authorized dispatch export. Tool A lists event E92 as a delivery confirmation. Tool B reports no E92 row. The underlying app database uses SQLite in write-ahead logging mode, which records certain changes in an accompanying file before those changes are transferred into the main database file. The supplied package contains the main database and its associated write-ahead log.

Both reports cite the same package identifier, but Tool B’s input log shows that its pass received only the main database. Preserve that run and its inventory. On a documented working copy that retains the associated files, examine the database view using the laboratory’s SQLite method and record the row reference and version. The working-copy view contains E92. That confirms a source-state difference in the documented runs and provides a row to interpret.

The row stores event code 8 under version 6 of the fictional app schema. The version 6 guide describes code 8 as a request to issue a delivery receipt. A version 5 guide describes code 8 as receipt acknowledged. The words in Tool A’s report resemble the older meaning, but the output does not reveal its mapping rules. Save the source field, both guides and the exact tool label.

In a controlled version 6 test export, an attempted receipt request shows code 8, and a separately observed acknowledgment has code 9. Use both cases to check that the mapping distinguishes the events relevant to the examination. Preserve the application build, schema version and fixture references. A fixture from a different schema or with only one type of event would provide weaker evidence about the disputed mapping.

E92 belongs to schema 6 in the exercise. Its verified code supports a request to issue a receipt, while acknowledgment remains unresolved in the supplied case material.

The verified working copy contains a request event for E92. The supplied evidence leaves acknowledgment unresolved. Report that Tool B omitted E92 in the documented main-file-only run and that Tool A’s classification differs from the verified event interpretation. If other case findings rely on the same label, review their schema and source state before correcting them. Keep rerun outputs separately identified so the reviewer can reconstruct which inputs produced each display.