Arc-Fault Circuit Interrupter (AFCI)

Definition

A circuit protection device required by NFPA 70 (US NEC) in specified residential circuits, designed to detect the signature current waveform of series arcing in degraded wiring and interrupt the circuit before ignition-level heat is generated.

Standard
NFPA 70 (US National Electrical Code)
Function
Detects series-arc waveform signature
Application
Specified residential circuits
Purpose
Interrupt circuit before ignition-level heat

Common questions

How does an AFCI differ from a standard circuit breaker?+

A standard breaker trips on sustained overcurrent, which a low-level series arc from degraded insulation often does not produce, while an AFCI analyzes the current waveform for the erratic, high-frequency signature characteristic of arcing and trips before enough heat accumulates to ignite nearby material.

Does the presence of an AFCI on a circuit rule out electrical arcing as a fire cause?+

No, because AFCIs can fail, be miswired, bypassed, or simply not cover the specific circuit involved, so investigators still document the device's presence and test its function rather than assuming it prevented an arc fault.

Related terms

Conveyor Belt Slip Fire
An industrial fire caused when a stationary conveyor belt is driven against a rotating roller, generating frictional heat concentrated at the contact...
Frank-Kamenetskii Model
A mathematical model (1939) for predicting the critical geometry above which a self-heating material will undergo thermal runaway to ignition, based on...
Glowing Connection
A loose or corroded electrical connection with elevated contact resistance that generates localised heat by Joule heating without increasing circuit current sufficiently...
Ground Current
The spread of lightning strike current outward through the soil from the grounded strike point, generating potential differences that can damage electrical...
Lithium-Ion Thermal Runaway
A self-reinforcing exothermic reaction within a lithium-ion cell, triggered by mechanical damage, overcharge, or elevated temperature, that propagates from cell to cell...
NFPA 51B
The National Fire Protection Association's Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, specifying minimum precautions including combustible clearance...
Reduced Ignition Propensity (RIP)
A cigarette design standard, adopted in the US (2010), EU (2011), Australia (2010), and Canada (2005), requiring cigarettes to self-extinguish when placed...
Side Flash
A secondary lightning discharge from the primary lightning channel to a nearby conductor, caused by potential difference between the strike channel and...
Smouldering Combustion
A flameless, slow-propagating oxidative combustion front that can sustain itself for 30 minutes to several hours within a porous, combustible material (upholstery,...

Explained in

Your journey to becoming a forensic professional starts here.

Practice with mock tests, learn from structured notes, and get your questions answered by a global forensic community, all in one place.