Ventricular Fibrillation

Definition

Chaotic, ineffective cardiac electrical activity induced by alternating current (50-60 Hz) at 100-300 mA through the thorax. The primary mechanism of death in low-voltage domestic electrocution. Not self-terminating; requires defibrillation.

Trigger
AC current (50-60 Hz), 100-300 mA through the thorax
Context
Primary mechanism of death in low-voltage domestic electrocution
Nature
Chaotic, ineffective cardiac electrical activity
Reversibility
Not self-terminating; requires defibrillation

Common questions

Why is low-voltage AC particularly dangerous for triggering ventricular fibrillation compared with higher currents?+

The 50-60 Hz mains frequency sits in the range where the human heart is most susceptible to fibrillation, well below frequencies where tissue can no longer follow each cycle and well above frequencies that cause smooth tetanic contraction without disrupting cardiac rhythm. Direct current and very high-frequency AC are markedly less likely to induce fibrillation at comparable current levels.

How does the absence of self-termination affect a death investigation involving electrocution?+

Because fibrillation does not spontaneously resolve, a victim who is not promptly defibrillated will die from the arrhythmia itself even if the electrical contact was brief, which means investigators should not assume a short contact duration rules out electrocution as the cause of death.

Related terms

Arc Flash
Plasma discharge between a charged high-voltage conductor and an earthed object, reaching 10,000-20,000 K. Causes flash burns to skin, ignites clothing, and...
Can't Let Go Threshold
Current level (10-20 mA for AC) at which sustained tetanic muscle contraction prevents voluntary release of a gripped conductor. Critical in domestic-appliance...
Joule Burn
Thermal tissue injury at an electrical contact point, produced by the conversion of electrical energy to heat (Q = I²Rt). Characterised by...
Lichtenberg Figure
Branching, ferning erythematous skin pattern produced by superficial flashover of lightning current. Pathognomonic of lightning strike. Fades within 24-48 hours; early documentation...
Metallisation
Impregnation of vaporised conductor metal into the skin at a high-voltage electrical contact point. Identified by X-ray fluorescence or SEM-EDS. Allows matching...