Split-Sample Protocol

Definition

The practice of dividing a forensic extract into two portions before analysis, one for prosecution analysis and one archived for potential defence re-testing. Required by CPIA 1996 (UK), Brady disclosure obligations (US), and ENFSI guidelines (EU) to preserve the defence's right to independent testing.

Purpose
Preserve the defence's right to independent retesting
UK basis
CPIA 1996
US basis
Brady disclosure obligations
EU basis
ENFSI guidelines
Typical split
One portion for prosecution analysis, one archived

Common questions

What happens if a sample is too small to split?+

When the extract volume is insufficient for a true split, the analyst documents the shortfall and, where possible, retains a portion of the original unextracted material instead, so the defence still has something independent to test.

Does the split-sample protocol apply to DNA as well as chemical extracts?+

Yes, though DNA cases usually satisfy it by retaining an untested reference or crime-scene stain rather than splitting an extract, since PCR-based methods can consume very little material.

Related terms

EGDN (Ethylene Glycol Dinitrate)
A volatile nitrate ester component of dynamite-type commercial explosives. Its high vapour pressure and long soil migration distance make it a reliable...
Electron Ionisation (EI)
The standard ionisation mode in GC-MS, using a 70 eV electron beam in high vacuum to ionise and fragment vapour-phase analytes. Produces...
Energy-Dispersive XRF (ED-XRF)
An XRF configuration in which characteristic X-rays from all excited elements are detected simultaneously by a silicon drift detector. Used in handheld...
ENFSI FEL Network
The European Network of Forensic Science Institutes Forensic Explosives Laboratory Network, linking national forensic explosives laboratories across 18 EU member states. Maintains...
Selected Reaction Monitoring (SRM)
A triple-quadrupole LC-MS/MS acquisition mode in which Q1 selects a precursor ion, Q2 fragments it, and Q3 detects a specific product ion....
SEM-EDX
Scanning electron microscopy with energy-dispersive X-ray spectroscopy. The electron beam excites characteristic X-rays from each element present in the target grain, giving...
Spheroidal Propellant Particle
A smooth, approximately spherical particle of ball-type smokeless powder 50-300 micrometres in diameter, identifiable under SEM by its distinctive morphology. Presence in...
Suppressed Conductivity IC
An ion chromatography detection method in which a membrane suppressor chemically neutralises the background eluent conductivity, leaving only the analyte ions as...
SWGMAT
Scientific Working Group for Materials Analysis, a US forensic science standards body (now succeeded by the OSAC Explosives Subcommittee). Published the Forensic...

Explained in

Your journey to becoming a forensic professional starts here.

Practice with mock tests, learn from structured notes, and get your questions answered by a global forensic community, all in one place.