Skip to content

Isotope Ratio Analysis

Definition

Measurement of relative abundances of two or more isotopes of an element to 0.01 to 0.5 percent precision. Lead ratios fingerprint the ore deposit a bullet was cast from, 87Sr/86Sr traces geographic origin, and 235U/238U anchors nuclear forensic attribution. Quadrupole ICP-MS reaches roughly 0.1 percent precision; multicollector sector instruments at BARC reach a few parts per million.

Typical precision
0.01 to 0.5 percent
Bullet lead use
Fingerprints ore-deposit origin
Provenance marker
87Sr/86Sr
Instrument precision
Quadrupole ICP-MS ~0.1%; MC sector instruments finer

Common questions

How does isotope ratio analysis differ from elemental composition analysis of a bullet?+

Elemental analysis (as in the retired bullet-lead comparison method) measures trace-element concentrations, which can vary within a single production batch. Isotope ratio analysis instead measures the ratio of lead isotopes, which reflects the geological origin of the ore and is far more stable within a source, giving a more defensible provenance signal.

Why does provenance work need instruments with such fine precision?+

Isotope ratios between different ore sources or geographic regions can differ by only a fraction of a percent, so distinguishing one source from another requires an instrument precise enough to resolve those small differences reliably, which is why multicollector sector instruments outperform standard quadrupole ICP-MS for this specific application.

Related terms

Collision and Reaction Cell (CRC)
A pressurised cell between the skimmer and the quadrupole, charged with helium for kinetic-energy-discrimination collision mode or with hydrogen, ammonia or oxygen...
Inductively Coupled Plasma (ICP)
An argon discharge sustained at 6000 to 10000 K by an RF coil at 27.12 MHz wrapped around a quartz torch. Argon...
Optical Emission Spectrometry (OES)
Detection arm in which excited atoms emit photons at characteristic wavelengths as they relax. A polychromator separates the light by wavelength and...
Polyatomic Interference
An ion formed in the plasma at the same nominal mass as a target analyte, for example argon-oxide on iron-56, argon-chloride on...
Quadrupole ICP-MS
Detection arm in which positive ions are extracted from the plasma through sampler and skimmer cones into a quadrupole mass filter that...

Explained in

Your journey to becoming a forensic professional starts here.

Practice with mock tests, learn from structured notes, and get your questions answered by a global forensic community, all in one place.